Engineering guide

How to size a fused silica viewport window for pressure or vacuum: the formula, a thickness table, and the mounting and surface rules that decide service life.

Quick Answer: The thickness of a fused silica window is set by the unsupported diameter, the pressure difference across the glass, how the edge is held, and the tensile stress you allow. A flat window bends under pressure and fails on the face that goes into tension, not on the face that is pushed.

  • Thickness scales with diameter. At the same pressure and allowable stress, doubling the open aperture doubles the thickness.
  • Thickness scales with the square root of pressure. Four times the pressure needs twice the glass.
  • Screening example: a 100 mm open aperture under 1 bar (full vacuum against atmosphere) needs about 5 mm at an allowable stress of 12 MPa with a simply supported edge.
  • The tables are not a rating. A pressurized window needs a safety factor, shielding and review by the person responsible for the system.

Written by the FGQuartz Engineering Team · Updated November 2026

On this page: Why windows bend · Formula · Thickness table · What the formula leaves out · Mounting · What to send · When a window is wrong · FAQ

Why a window is a bending problem

A flat window under pressure behaves like a circular plate loaded on one face. The glass bows toward the low-pressure side. The pressure face is in compression, where fused silica is very strong (about 1,100 MPa). The opposite face, at the center, is in tension, and that is where a window fails.

Fused silica is brittle, and its tensile strength is controlled by surface flaws rather than by the bulk. So the limit is the allowable tensile stress on that one face. Typical values for FGQuartz fused silica are on the technical specifications page: design tensile stress 48 MPa, Young’s modulus 72 GPa, Poisson’s ratio 0.17.

The formula

For a circular window with unsupported radius r and uniform pressure difference q, the peak tensile stress is:

σ = k × q × r² / t²

Solving for thickness:

t = r × √( k × q / σallow )

Edge condition k (ν = 0.17) When it applies
Simply supported 1.19 Window rests on a compliant gasket and is held by a retaining ring that does not clamp the edge rigidly. The conservative choice.
Clamped 0.75 Edge is held rigidly. The peak stress moves to the edge and is sensitive to how evenly the clamp loads the glass.

The k values are the classical thin-plate results found in standard references such as Roark’s Formulas for Stress and Strain. The formula assumes small deflection and a flat, defect-free surface. The unsupported diameter is the open aperture inside the seat or gasket, not the full diameter of the glass.

Screening table: minimum thickness

The table uses simple support (k = 1.19) and an allowable stress of 12 MPa, which is the 48 MPa design stress divided by an illustrative safety factor of 4. Your own factor depends on your risk assessment, applicable codes and confidence in the surface condition. Treat 12 MPa as an example, not a recommendation.

Unsupported diameter 1 bar (full vacuum) 5 bar 10 bar
50 mm 2.5 mm 5.6 mm 7.9 mm
100 mm 5.0 mm 11.1 mm 15.7 mm
150 mm 7.5 mm 16.7 mm 23.6 mm
200 mm 10.0 mm 22.3 mm 31.5 mm

For a rigidly clamped edge, multiply the thickness by 0.79. For a different allowable stress, scale by the square root of (12 ÷ your value). Pressures are differences across the window: a vacuum chamber with atmosphere outside sees about 1 bar.

Worked example. A vacuum viewport has a 100 mm open aperture (r = 50 mm) and carries 1 bar (0.1 MPa). With k = 1.19 and 12 MPa allowable:

t = 50 × √(1.19 × 0.1 ÷ 12) = 50 × 0.0996 ≈ 5.0 mm.

A 6 mm window would add margin. Choosing between 5, 6 and 8 mm then comes down to the safety factor, the edge condition and cost.

What the formula leaves out

  • Surface flaws. A scratch or chip on the tension face can set the real strength. On a vacuum viewport that is the vacuum-side face. Specify scratch and dig on that face and protect it in handling and cleaning.
  • Edges. Chamfer or round the edge. A sharp or chipped edge is where cracks start, especially under clamp load.
  • Load duration. Glass under sustained tension can fail at a lower stress than in a short test, especially in humid air. Passing a pressure test does not prove years of steady load.
  • Temperature. A hot center with a cooler clamped edge adds thermal stress to pressure stress. As a rough estimate a fully constrained surface sees about 0.048 MPa per kelvin of gradient, or about 4.8 MPa for 100 K.
  • Optical requirements. Thickness also changes absorption and focus. For UV or IR work, choose the grade first; see the JGS1, JGS2 and JGS3 selection guide.

Mounting rules that protect the glass

  1. No metal-to-glass contact. Use a compliant gasket between the glass and the flange on both faces.
  2. Spread the load. Tighten the retaining ring evenly. Point loads and uneven bolt torque create tension where the glass is weakest.
  3. Leave room for movement. Metal expands much more than fused silica. Allow edge clearance so a heated housing does not squeeze the window.
  4. Keep the seat flat. A warped or rough seat turns a uniform load into bending and point contact.
  5. Add shielding. A broken pressurized window can throw fragments. Use a guard according to your site’s safety rules.

What to send with your request

Item Why it matters
Open aperture diameter (or shape and size if not round) Sets the radius in the formula
Pressure difference, and whether it can reverse Sets stress and which face is in tension
Steady or cycling, and cycles per day Sustained and cyclic loads need more margin
Temperature profile and any hot or cold spots Adds thermal stress
Wavelength range and optical requirements Grade, flatness, parallelism, surface quality
Mount design: gasket, ring, flange drawing Edge condition and load path
Quantity and inspection needs Planning and documentation

When a single window is the wrong design

For very large apertures or high pressure the required thickness becomes impractical and costly. Common alternatives are a smaller aperture, a recessed or stepped seat, or a support grid. If a glass failure would be dangerous, a design that does not rely on one unsupported pane is usually better. Pressure-equipment rules differ by country and application, so check which apply to your complete assembly.

Frequently asked questions about fused silica window thickness

Short answers written to stand alone.

How thick should a fused silica vacuum window be?

It depends on the open aperture, edge support and the stress you allow. As a screening example, a 100 mm open aperture under 1 bar needs about 5 mm at an allowable stress of 12 MPa with simple support. Confirm the final thickness for your exact design.

Why does window thickness scale with diameter?

Bending stress is proportional to the square of the radius divided by the square of the thickness. At a given pressure and allowable stress, thickness therefore scales in direct proportion to radius.

Which face of the window sees the highest tensile stress?

The face away from the pressure, at the center for a simply supported window. For a vacuum viewport with atmosphere outside, that is the vacuum-side face.

Is a clamped window stronger than a supported one?

On paper, yes, because the peak stress is lower. In practice an uneven clamp can load the glass badly, so many designs treat the window as simply supported on a compliant gasket and use the conservative k value.

What allowable stress should I use for fused silica?

A commonly used design value is about 48 MPa. It is a design value, not a guaranteed failure limit, and a flawed or long-loaded surface can fail lower. You still need a safety factor on top of it, set by your own risk assessment and applicable codes.

Does the same thickness work at high temperature?

Not automatically. Thermal gradients add stress to the pressure stress. Give the full temperature profile, including hot and cold spots, not only the peak.

What gasket should I use under a quartz window?

Use a compliant gasket on both faces so there is no metal-to-glass contact and the clamp load is spread evenly. The right material depends on temperature, vacuum level and chemistry, so share your conditions with the engineering team.

Does FGQuartz make custom viewport windows?

Yes. We cut, grind, drill, machine and polish fused silica windows to your drawing, from a single prototype. There is no minimum order quantity, and quotes are typically returned within 24 business hours.

Specify the window, then the mount

FGQuartz cuts, grinds, drills, machines and polishes fused silica windows and plates to your drawing, in JGS1, JGS2 and JGS3, from SiO₂ ≥ 99.99% material, in round, square, rectangular and custom outlines and standard formats up to 1200 mm × 1200 mm. Send the aperture, pressure, temperature and wavelength, and the engineering team reviews thickness, edge finish and surface quality before any glass is cut.

There is no minimum order quantity, prototypes start from one piece, and quotes are typically returned within 24 business hours.